Ana səhifə

For highway construction oregon department of transportation salem, oregon


Yüklə 2.6 Mb.
səhifə19/19
tarix25.06.2016
ölçüsü2.6 Mb.
1   ...   11   12   13   14   15   16   17   18   19

Obtain items and quantities from the Designer. Fill all the required blanks. Delete items that do not apply.)
Item Quantity
"" HDPE Porous Pavers ____ Sq. Ft.

Blended Compost and Topsoil MixtureBiofiltration Soil Media ____ Cu. Yd.

Plastic Board Flow Spreader ____ Foot

Concrete Basin Flow Spreader ____ Each

Rock Basin Flow Spreader with Stone Embankment ____ Cu. Yd.

Rock Basin Flow Spreader with Riprap ____ Cu. Yd.

Drainage Geotextile, Type 1 ____ Sq. Yd.

Riprap Geotextile, Type 1 ____ Sq. Yd.

Loose Riprap, Class ____ ____ Cu. Yd.

Concrete Storm Sewer Manhole (Flow Splitter) ____ Each

Ditch Inlet, Type D ____ Each

____ Inch ____ Storm Sewer Pipe ____ Foot


Payment
01092.90  Payment - The accepted quantities of work performed under this Section will be paid for at the Contract lump sum amount for the item "Water Quality Swale".
Payment will be payment in full for furnishing and placing all materials, and for furnishing all equipment, labor, and incidentals necessary to complete the work as specified.

SECTION 02110 - POSTS, BLOCKS, AND BRACES
(Follow all instructions. If there are no instructions above a subsection, paragraph, sentence, or bullet, then include them in the project but make necessary modifications to only include project specific specifications. Delete specifications that do not apply to the project.)
Comply with Section 02110 of the Standard Specifications modified as follows:
02110.40(a)  Grading - Replace the Douglas Fir and Hem Fir grading requirements with the following grading requirements:
Species 4" x 4" 4" x 6" 6" x 6"

and Larger
Douglas Fir 124 c WCLIB 123 c WCLIB 131 cc WCLIB

42.12 WWPA 62.12 WWPA 80.12 WWPA


Hem-Fir 124 c WCLIB 123 c WCLIB (not allowed)

42.12 WWPA 62.12 WWPA (not allowed)



SECTION 024400587 -- JOINT MATERIALSBRIDGE RAILS

(Follow all instructions. If there are no instructions above a subsection, paragraph, sentence, or bullet, then include them in the project but make necessary modifications to only include project specific specifications. Delete specifications that do not apply to the project.)
Comply with Section 024400587 of the Standard Specifications modified as follows:
Add the following subsection:
024400587.1380  Expanded Rubber Filler PadMeasurement -- Provide expanded rubber filler pad according to ASTM D1056, Grade 2A1Add the following to the end of this subsection:.
The estimated quantity of bridge rail is:
(List rail type as the pay item name. Obtain information from the Bridge Designer.)
Quantity

Structure Rail Type (Foot)
Bridge No. ________

Bridge No. ________




SECTION 02630 - BASE AGGREGATE

Comply with Section 02630 of the Standard Specifications modified as follows:


02630.10(a)  Grading - In Table 02630-01, add the following sieve size line before the No. 10 sieve size line and add the following footnote at the end to the table:
No. 4 *     
* Report percent passing sieve when no grading requirements are listed

SP2910 (03-31-08) (Use this Section only when

Type "W9" signs are required.)
SECTION 02910 - SIGN MATERIALS
(Follow all instructions. If there are no instructions above a subsection, paragraph, sentence, or bullet, then include them in the project but make necessary modifications to only include project specific specifications. Delete specifications that do not apply to the project.)
Comply with Section 02910 of the Standard Specifications modified as follows:
02910.02  Types of Signs - Replace the "W9" sign type with the following:
"W9" Silver-white Type III or Type IV sheeting background with blue nonreflective screened or cut-out permanent legend.

SP2920 (03-31-08) (Use this Section only when standard loop feeders

exceed NEC maximum fill rates on small existing

conduits. Check with Signal Designer before using.)
SP2920 (03-31-08) (Use this Section only when standard loop feeders

exceed NEC maximum fill rates on small existing

conduits. Check with Signal Designer before using.)
SECTION 02920 - COMMON ELECTRICAL MATERIALS

(Follow all instructions. If there are no instructions above a subsection, paragraph, sentence, or bullet, then include them in the project but make necessary modifications to only include project specific specifications. Delete specifications that do not apply to the project.)
Comply with Section 02920 of the Standard Specifications modified as follows:
02920.22  Cable - Add the following sentence to the end of the "Loop Feeder Cable" bullet:
When shown, construct loop feeder circuits of two-conductor No. 18 AWG twisted pair shielded cable with drain wire conforming to IMSA 50 2.

02920.22  Cable - Add the following sentence to the end of the "Loop Feeder Cable" bullet:
When shown, construct loop feeder circuits of two-conductor No. 18 AWG twisted pair shielded cable with drain wire conforming to IMSA 50 2.

SP2925 (06-12-08) (Use this Section only when subsections .42,

.51, .65(a-1), .65(a-2), or .68 are required.
SECTION 02925 - TRAFFIC SIGNAL MATERIALS
(Follow all instructions. If there are no instructions above a subsection, paragraph, sentence, or bullet, then include them in the project but make necessary modifications to only include project specific specifications. Delete specifications that do not apply to the project.)
Comply with Section 02925 of the Standard Specifications modified as follows:

(Use the following subsection .42 when traffic signal control devices are required. Obtain information from the Signal Designer.)
02925.42  Traffic Signal Control Devices - Add the following to the end of this subsection:
The following changes are made to the September 2001 Standard Specifications for Microcomputer Signal Controller:

(Use the following Chapter 2 lead in sentence and 2.1.10 on all off-system, local Agency funded or developed projects.)
Replace Chapter 2, Section 1, Unit 10 with the following:
(Fill in the blank with CONTRACTOR, COUNTY, CITY, etc. as appropriate.)
2.1.10 The traffic signal control program and PROMS with PROM module for the Model 170E will be furnished by the _______________
(Use the following for all signal cabinets.)
3.1.6.1 Replace "15 amps" with "10 amps"

(Use the following when auxiliary files are needed in Model 332 cabinets.)
6.1.1.1 Add the following to the listed items: Auxiliary output file
(Use the following when auxiliary files are needed in Model 334 cabinets.)
6.1.1.2 Add the following to the listed items: Auxiliary output file
(Use the following if a Model 400 modem is not required in Model 332 or 334 cabinets.)
6.1.1.4 In the first sentence, remove "with Model 400 Modem".
(Use the following when Model 332 or 334 cabinets are used.)
6.5.2.1 Replace the last sentence with the following:
All spade connectors on wires connecting to the input panel (terminal blocks TB1 through TB10 and DC ground bus) and/or input files (terminal blocks T1 through T15) shall be crimped and soldered to the wires.
(Use the following when auxiliary files are needed in Model 336s intersection cabinets.)
7.1.1.1 Add the following to the listed items: Auxiliary output file
(Use the following when auxiliary files are needed in Model 336S ramp meter cabinets.)
7.1.1.2 Add the following to the listed items: Auxiliary output file
(Use the following if a Model 400 modem is not required in Model 336 or 336S cabinets.)
7.1.1.4 In the first sentence, remove "with Model 400 Modem".
(Use the following when Model 336 or 336S cabinets are used.)
7.5.2.1 Replace the last sentence with the following:
All spade connectors on wires connecting to the input panel (terminal blocks TB1, TB2, and DC ground bus) and/or input files (terminal blocks T1 through T15) shall be crimped and soldered to the wires.
(Use the following Chapter 8, Section 3 on projects with phone equipped cabinets. Choose either phone line or cellular phone line. Delete the method that does not apply.)
Add the following new Section to Chapter 8:
SECTION 3 - TELEPHONE EQUIPPED CABINETS
8.3.1 General Requirements
(Use the following 8.3.1.1 and 8.3.1.2 for cellular phone lines.)
8.3.1.1 Provide and install equipment as shown on Standard Drawing TM423, (Telephone equipped cabinet). Use the following amended parts list:
MC 480 installation kit - #FLN3181

Cellular connector - #S1936C

Transceiver- #19024NAASC.
8.3.1.2 Cellular phone shall have local phone number for the "Installed Signal" location.
(Use the following 8.3.1.1 for phone lines (non-cellular).)
8.3.1.1 Data transmission between the controller and the remote control locations shall be by standard dial-up telephone line. Transmission rate shall support a variable transmission rate determined by autosyncing of the modem. The modem shall operate with the controller at any speed or settings the modem establishes with the external source. The remote station shall have a dial-up telephone line at the remote control. Provide one auto-dial/auto-answer external modem (28,000 bps minimum) for the controller.
(Use the following lead-in paragraph and Chapter 9 on projects when 2070L controllers are required.)
Add the following new Chapter 9:
CHAPTER 9 - MODEL 2070 CONTROLLER UNIT
SECTION 1 - MODEL 2070L CONTROLLER
9.1.1 Unit Chassis
9.1.1.1 The 2070L Controller shall consist of a 2070 Chassis meeting the following requirements:
1. Lite Cage

2. 2070-1B CPU Module

3. 2070-2A C1 Field I/O Connector Module

4. 2070-4B Power Supply Module

5. 2070-3B 8x40 LCD Display Module

6. 2070-6A 1200 baud Modem Module

7. 2Mb Data Key
9.1.2 Controller and Module
9.1.2.1 The 2070L Controller and module shall meet the following specifications:
1. Caltrans 2002 TEES

2. TEES Errata 1, October 27, 2003

3. TEES Errata 2. June 8, 2004

4. Caltrans QPL Listing, October 2006

5. OS-9 Operating System version 3.3 (Ethernet Capable)

6. Controller Boot Code Compatible with NW Signal Voyage Controller Firmware and all included features

7. Tested and approved Boot Codes are:
a. Econolite - Boot Code 2002 V1.01.08.02b or later

b. Simens/Eagle - Boot Code OS0 V3.3.0 Operating System 7.0.0.0.0.15 or later


(Use the following subsection .51 on projects when new vehicle signals or when new pedestrian signals are required. Check with Signal Designer before using.)
02925.51  Traffic Signal Lamps - Add the following to the end of this subsection:
Provide the following LED modules:
Vehicle Signals
Indication 8 Inch Lens 12 Inch Lens

Color Type Type
Red LED 1 LED 1

Yellow LED 1 LED 1

Green LED 1 LED 1
Pedestrian Signals 2
Indication Side by Side Countdown

Color Type Type
Hand LED 3 LED 4

Walking Man LED 3 LED 4

Numbers  LED 4
1 Flange mount LED modules.
2 Pedestrian signal LED modules may be a combination of indication in one module or single indication in separate modules.
3 Side by side LED modules are a combination of indication (both the hand and walking man in one module).
4 Countdown LED modules are a combination of indication (both the hand and walking man overlaid on the left with numbers on the right in one module).
(Use the following subsections .65(a-1) and .65(a-2) on projects when new pedestrian signals are required. Check with Signal Designer before using.)
02925.65(a-1)  Standard - Replace this subsection with the following subsection:
(1)  Standard - The standard light source shall meet the requirements of 02925.51.
02925.65(a-2)  Count Down - Replace this subsection with the following subsection:
(2)  Count Down - The count down shall meet the requirements of 02925.51.
(Use the following lead-in paragraph and subsection .68 on projects when new vehicle signals or new pedestrian signals are required. Check with Signal Designer before using.)
Add the following subsection:
02925.68  Signal Head Covers - Provide signal head covers that:


  • Are yellow prefabricated nylon.

  • Completely cover the head, visors, and backplate.

  • Include a fine mesh insert for signal testing.

  • Have integral elastic bands and clips to secure the covers to the signal.



SP2926 (created by CWR)
SECTION 02926 -  LAMPS, BALLASTS, AND LUMINAIRES

Comply with Section 02926 of the Standard Specifications modified as follows:


Add the following subsection:
02926.53(c) Underdeck Luminaires - Add the following subsection:
The underdeck luminaire shall have an ovaloval cast aluminum ballast housings and be painted with a corrosion resistance paint. The luminaire shall include a completely prewired integral ballast latched to separate optical assembly with corrosion resistant hardware. It shall be so constructed that luminaire will be UL 1572 listed for wet locations. For actual mounting details, see the bridge plans and the illumination plans.
Provide underdeck luminaires from the following manufacturer (or an approved equal):


      • Hubbell Lighting, Christiansburg, VA 24073, (540) 382-6111 - Model Euroluxe BOS-01.


*****
1   ...   11   12   13   14   15   16   17   18   19


Verilənlər bazası müəlliflik hüququ ilə müdafiə olunur ©atelim.com 2016
rəhbərliyinə müraciət